Testing and Processing Equipment Including Polished Plates, Evacuable Pellet Dies, Test Cylinder Outfits (TCO’s) and Many Other Items for Labs Laboratory Press Parts and Accessories for Carver Presses |
||
Polished Pressing Plates Polished stainless steel pressing plates for laminating applications. (Picture shows all 3 different sizes available) |
||
Evacuable Pellet Dies Used with Pellet Presses to form the pellets for use in IR and x-ray spectroscopy. The stainless steel die includes a fitting for vacuum source connection. (6, 12, 13, 25, 31 and 40mm dies available.) Not recommended for use in heated presses. |
||
Test Cylinder Outfits (TCO’s) No. 2090-0 – 1.125″ Unheated Stainless Steel Test Cylinder Outfit (TCO’s)No. 2091-5 – 2.25″ Unheated Stainless Steel Test Cylinder Outfit (TCO’s) Consult factory for special test cylinder sizes. For molding, forming bricks, briquettes, pressure forming, crushing, pressing plant and animal tissues, fluid extraction, extrusion and flow tests. Note: For use in Carver standard presses (excluding pellet presses) Not recommended for use in heated presses. |
||
Test Cylinder Outfits (TCO’s)No. 2090.1 Filter Pads
12 Filter pads for 1.125″ sized test cylinders No. 2091.1 Filter Pads 12 Filter pads for 2.25″ sized test cylinders |
||
Plate Kit AssembliesNo. 5021 KBr Buffer Plate and 6″ x 6″ Single Hardened Steel Platen with Centering Grooves
No. 5022 KBr Buffer Plate and 9″ x 9″Single Hardened Steel Platen with Centering Grooves Recommended for use with pellet dies and test cylinder outifts. Picture shows 5021 installed in 3851 press. |
||
No. 3874 Vacuum Pump Used with pellet presses to evacuate gases from pellet dies. Includes vacuum gauge and connecting tubing. Available in 115V or 230V. (please specify) |
||
No. 5456 Proppant Crush Test CylinderThis die is designed to test proppant used in the hydraulic fracturing process. Based on ISO 13503-2:2006(E) Crush Cell.Cell: 2″ ID x 3.38″ tall including removable base, wall thickness is >0.5″Piston: 3.5″ tallAll parts constructed of D2 Tool Steel, hardened to 52-56 Rockwell C | ||
No. 2092 Swivel Bearing Plate Carver presses are frequently used for crushing and breaking tests of standard 2″ x 2″ cubes and 2″ x 4″ cylinders of concrete samples or similar crushing tests. Swivel Bearing Plates adjust slightly to the sample to assure proper application of pressure. For unheated models only. Requires safety shield. |
||
No. 818744C Pharmaceutical Punch and Die Holder This punch and die holder permits testing of pellet and tablet samples. It works with standard BB2 type tooling in most Carver presses, including Auto Series presses. The set includes an anodized aluminum holding fixture, steel shims to adjust for various size samples, and an anodized aluminum ejector. (Does not include dies) Not recommended for use in heated presses. |
||
No. 2094 Cage Equipment When using Carver presses to press moisture from fibrous materials, extract fats, oils or juices from vegetable or animal tissues, splitting chilled oils or separating crystals from liquors, these accessories are useful. Cage equipment consists of cylinder, plunger, steel discs, felt discs, tray and bulb syringe. Requires a daylight opening of 16 inches. Not recommended for use in heated presses. |
||
No. 237005 Stainless Steel Pan Fluid pan for use with Test Cylinder Outfits.The stainless steel pan captures the release fluid. Also included with purchase of unheated Test Cylinder Outfits. |
||
Heated Test Cylinder Outfits
No. 2472-1 (115V) & 2472-2 (230V) 1.125″ ID No. 2417-1 (115V) & 2417-2 (230V) 2.25″ ID Complete with band heater, insulation, thermostat, stainless steel housing and handle. Max. force 35,000 lbs for 1.125″ and 99,000 lbs for the 2.25″ applied load @ 400°F. (Not for use with Model 4350 Series, Mini C, Model C Presses or Heated Presses. This TCO may be used in an unheated Model M with plate kit 5022) Not recommended for use in heated presses. (Picture shows 2472) |
||
Reference Table | ||
Polished Plates and Blotters (for laminating applications) | ||
235020 | Polished Stainless Steel plate with #8 polished mirror finish on one side and 2-3 micro-inch finish, 6″ x 6″ x .03″ thick | |
235021 | Polished Stainless Steel plate with #8 polished mirror finish on one side and 2-3 micro-inch finish, 9″ x 9″ x .03″ thick | |
235022 | Polished Stainless Steel plate with #8 polished mirror finish on one side and 2-3 micro-inch finish, 9″ x 12″ x .03″ thick | |
235023 | Polished Stainless Steel plate with #8 polished mirror finish on one side and 2-3 micro-inch finish, 12″ x 12″ x .03″ thick | |
823003 | Protective blotter, 6″ x 6″ | |
823012 | Protective blotter, 9″ x 9″ | |
823005 | Protective blotter, 9″ x 12″ | |
823001 | Protective blotter, 12″ x 12″ | |
Pellet Dies | ||
4417 | 6mm pellet die, constructed of 440 SS, 3,500 lbs. Maximum Applied Force | |
4946 | 12mm pellet die, constructed of 440 SS, 13,000 lbs. Maximum Applied Force | |
3619 | 13mm pellet die, constructed of 440 SS, 18,000 lbs. Maximum Applied Force | |
4369 | 25mm pellet die, constructed of 440 SS, 47,000 lbs. Maximum Applied Force | |
3902 | 31mm pellet die, constructed of 440 SS, 60,000 lbs. Maximum Applied Force | |
3876 | 40mm pellet die, constructed of 440 SS, 70,000 lbs. Maximum Applied Force | |
Unheated Test Cylinder Outfits (TCO’s) | ||
2090-0 | 1.125″ ID x 3″ high, Test Cylinder Outfit, 440 SS, 19 tons Maximum Applied Force | |
2091-5 | 2.25″ ID x 3″ high, Test Cylinder Outfit, 440 SS, 51 tons Maximum Applied Force | |
Heated Test Cylinder Outfits (TCO’s) | ||
2472-1 | 1.125″ ID x 3″ high, Heated Test Cylinder Outfit, Maximum force 35,000 lbs applied load at 400 deg F, 115V | |
2472-2 | 1.125″ ID x 3″ high, Heated Test Cylinder Outfit, Maximum force 35,000 lbs applied load at 400 deg F, 230V | |
2417-1 | 2.25″ ID x 3.75″ high, Heated Test Cylinder Outfit, Maximum force 99,000 lbs applied load at 400 deg F, 115V | |
2417-2 | 2.25″ ID x 3.75″ high, Heated Test Cylinder Outfit, Maximum force 99,000 lbs applied load at 400 deg F, 230V | |
Proppant Crush Test Cylinder | ||
5456 | 2″ ID Proppant Crush Test Cylinder based on ISO 13503-2:2006(E) | |
Available Plate Kit Assemblies | ||
Part Number | Description | Recommended For |
5021 | Includes: (1) KBr Buffer Plate (90mm diameter), mounts to the Top Bolster and (1) 6″ x 6″ hardened steel plate with centering grooves, mounts to the Moving Bolster on top of ram. | Used with Dies and Test Cylinder Outfits |
5022 | Includes: (1) KBr Buffer Plate (90mm diameter), mounts to the Top Bolster and (1) 9″ x 9″ hardened steel plate with centering grooves, mounts to the Moving Bolster on top of ram. | Used with Dies and Test Cylinder Outfits |