Double bending beam load cell. Measuring element from aluminium. 3000 divisions O.I.M.L. R60 class C. Protected IP 66 (EN 60529). Single point load cell. High accuracy with off-center loads.
- Double bending beam load cell
- Measuring element from aluminium
- 3000 divisions O.I.M.L. R60 class C
- Protected IP 66 (EN 60529)
- Single point load cell. High accuracy with off-center loads
- Aplications:
- platforms up to 500×500 mm (600×600 mm 50kg)
- personal scales
- platforms up to 400×400 mm
- medical scales
Technical specification
Nominal capacities | 100-200-300 | kg |
---|---|---|
Accuracy class | 3000 | n. OIML |
Minimum dead load | 0 | %Ln |
Service load | 120 | %Ln |
Safe load limit | 150 | %Ln |
Total error | < ±0.017 | %Sn |
Repeatability error | < ±0.01 | %Sn |
Temperature effect on zero | < ±0.01 | %Sn/5K |
Temperature effect on sensitivity | < ±0.006 | %Sn/5K |
Creep error (30 minutes) | < ± 0.016 | %Sn/5K |
Temperature compensation | -10 to +40 | ° C |
Temperature limits | -20 to +70 | ° C |
Nominal sensitivity (Sn) | 2 ± 10% | mV/V |
Nominal input voltage | 10 | V |
Max. input voltage | 15 | V |
Input impedance | 400 ± 20 | Ohm |
Output impedance | 350 ± 3 | Ohm |
Počáteční hodnota nuly | < ± 2 | %Sn |
Insulation resistance | > 5000 | MOhm |
Max.deflection (at Ln) | 0.3 – 0.5 | mm |